πŸ“ FL Fixture Rough-In Height Reference

Standard & ADA rough-in heights for all plumbing fixtures β€” FL code requirements, toilet rough-in distance, shower valve placement

ADA + STANDARD
Rough-In Calc
All Fixtures
FL Code
Quote
πŸ“ Toilet Rough-In Distance Calculator

Toilet rough-in distance is measured from the finished wall to the center of the closet flange (drain). This is NOT the toilet-to-wall gap β€” it's the drain centerline from the wall behind the toilet.

Standard: 12". Older FL homes may have 10" or 14". Measure from wall to drain center.

Leave 0 if measuring to finished wall face. Add 0.5" for tile, 4" for typical stud wall.

Toilet Rough-In Results
WALL 12" std TANK Rough-In Distance βŠ™ FLANGE CENTER Measure from finished wall to drain CL
🚿 Shower Valve Rough-In Calculator
Standard
ADA / Accessibility
Shower Valve Heights (from finished floor)
πŸ“‹ All Fixture Rough-In Heights
Standard
ADA / Accessibility
🚽 Toilet Rough-In Standards
Rough-InCommon InToilet AvailabilityNotes
10"Pre-1960s homesLimited selectionOlder FL plumbing
12"All erasFull selectionStandard β€” widest choice
14"Some older FLGood selectionLess common today
⚠️ Before toilet replacement: Always measure your existing rough-in distance. A 12" toilet CANNOT be used with a 10" rough-in (it will hit the wall). A 10" toilet can sometimes be used with a 12" rough-in using an offset flange β€” call your plumber first.
πŸ“Š Supply and Drain Quick Reference
FixtureCold SupplyHot SupplyDrain CL
Toilet6–8" from floor, leftN/A12" from wall (std)
Lav sink20" from floor, 4" R of CL20" from floor, 4" L of CL18–20" from floor
Kitchen sinkUnder sink boxUnder sink box15–17" from floor
ShowerValve centerValve center2" trap, floor level
Tub/shower28–32" from floor28–32" from floor6" from end wall
DishwasherUnder sinkN/AAir gap at sink
Washing machine48" from floor, L48" from floor, R34–36" standpipe ht
Water heaterCold: right sideHot: left sideFloor drain nearby
Hose bib24" from grade (exterior)N/AN/A
πŸ“‹ FL Plumbing & Accessibility Code
FPC Key Rough-In References

FPC 405.3.1 β€” Toilet location: Toilet shall be located a minimum of 15" from its centerline to any side wall, partition, or cabinet. This applies to BOTH sides. For ADA: minimum 18" from one side (transfer side).

FPC 405.3.2 β€” Toilet clearance: Minimum 21" clearance in front of toilet (measured to any obstacle). ADA requires 60" minimum turning radius or 30"Γ—48" clear floor space.

FPC 412.2 β€” Shower receptors: Shower floor shall slope uniformly to drain at 1/4" per foot minimum. Curb height 2" minimum. Threshold maximum 1/2" for accessibility compliance.

FPC 424.6 β€” Grab bar blocking: FL requires blocking or solid backing in shower/tub areas of new residential construction to allow future grab bar installation (FBC 11-4.23.4). 2Γ—8 blocking required between studs.

FPC 603.2 β€” Water heater location: Gas WH in garage requires 18" minimum elevation of ignition source above garage floor. Electric WH may be floor-mounted. Drip pan required for WH in conditioned space or above finished area.

ADA (ADA-ABA Guidelines / FBC Ch. 11)

FL Building Code Chapter 11 adopts the ADA Standards for Accessible Design for all new commercial construction and some residential. Key fixture requirements:

Lavatories (FBC 1109.2): Rim height max 34"; knee clearance min 27" high Γ— 30" wide Γ— 19" deep; clear floor space 30"Γ—48" in front; supply/drain insulated or covered to prevent burns.

Water closets (FBC 1109.4): Height 17"–19" to top of seat; 60" clear floor space side approach OR 66"Γ—56" for front approach; flush control on open side.

Shower stalls (FBC 1109.6): 36"Γ—36" for transfer shower or 30"Γ—60" for roll-in shower; seat required for transfer-type; controls between 15"–48" AFF; hand shower on 60" minimum hose.

Bathtubs (FBC 1109.5): Foot controls at 60" AFF; head controls at 60" AFF max 15" from foot wall; grab bars at 24" front, 12" back, side wall full length.

Rough-In Compliance Checklist
Toilet centerline β‰₯15" from side walls on both sides FPC 405.3.1 β€” minimum clearance from any wall, partition, or obstacle; ADA: 18" transfer side
Minimum 21" clear in front of toilet (30" ADA) FPC 405.3.2 β€” measured from toilet front to any obstruction; ADA requires 30"Γ—48" clear floor space
Shower floor slopes ΒΌ" per foot minimum to drain FPC 412.2 β€” uniform slope required; tile setter must maintain slope; test with water before tile grout
Grab bar blocking installed in tub/shower walls FBC 11-4.23.4 β€” 2Γ—8 blocking between studs at 33"–36" AFF required in FL new residential construction
Water heater drip pan installed where applicable FPC 501.6 β€” required when WH is in conditioned space or above finished ceilings; drain line to approved location
Lavatory center-of-drain 16"–18" from side wall FPC 405.4 β€” minimum 15" from side obstacles; standard 18" from wall to drain center; verify with fixture spec sheet
Shower valve anti-scald protection (ASSE 1016 / 1070) FPC 412.7 β€” pressure-balance or thermostatic valve required; max 120Β°F delivered to shower; verify lever handle direction
Supply stub-outs match fixture specification sheet Always verify supply spacing (typically 8" cold-to-hot on center) against actual fixture spec sheet before rough-in
All rough-in inspected before walls closed FL requires plumbing rough-in inspection before wall coverings are installed; inspector checks all stub-out heights, drain locations
0 / 9 items checked